IC Installed Cost

American Standard heat pump

4A6V8X36A1

PLATINUM 18

1 tracked program have AHRI-linked equipment records.

Eligibility belongs to the complete outdoor-and-indoor combination—not just this outdoor model. Check the AHRI reference and indoor model in the table before relying on a result.

Check this complete system in Connecticut

AHRI links below are discovery evidence. They do not compare every model suffix or required component. Use the guided check for a full equipment comparison.

130documented combinations
17.5–18SEER2 range
7.8–8.5HSPF2 range
1.67–1.91COP at 5°F range

AHRI-linked program records

Certified combinations

Showing 101–130 of 130. Performance values are combination-specific.

AHRI referenceIndoor unit / coilFurnaceSEER2HSPF2COP at 5°FCapacity at 5°FAHRI-linked list records
214253320 4PX*CU48BS3 None published 18 8.2 1.8 20,200 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253334 4TXCB006DS3 None published 18 8.2 1.8 20,800 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253336 4TXCB006DS3 None published 18 8.2 1.8 20,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253338 4TXCB006DS3 None published 18 8.1 1.8 19,900 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253340 4TXCB006DS3 None published 18 8.1 1.8 19,900 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253342 4TXCB006DS3 None published 18 8.2 1.8 20,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253344 4TXCB006DS3 None published 18 8.2 1.8 20,800 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253346 4TXCC005DS3 None published 18 8.2 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253348 4TXCC005DS3 None published 18 8.2 1.7 20,200 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253350 4TXCC005DS3 None published 18 8.2 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
214253352 4TXCC005DS3 None published 18 8.2 1.7 20,200 Btu/h Xcel Energy Colorado Heat Pump Rebates
214638914 4TXCB006DS3 None published 18 8.2 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
214638916 4TXCB006DS3 None published 18 8.2 1.8 20,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
214639982 4PX*BU48BS3 None published 18 8.5 1.8 20,200 Btu/h No stored match
214639984 4PX*BU48BS3 None published 18 8.5 1.8 20,200 Btu/h No stored match
214639986 4PX*BU48BS3 None published 18 8.5 1.8 20,600 Btu/h No stored match
214639992 4PX*CU36BS3 None published 18 8.2 1.8 20,200 Btu/h Xcel Energy Colorado Heat Pump Rebates
214639994 4PX*CU42BS3 None published 18 8.5 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
214639996 4PX*CU48BS3 None published 18 8.5 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
214640008 4TXCB006DS3 None published 18 8.5 1.8 21,000 Btu/h Xcel Energy Colorado Heat Pump Rebates
214640010 4TXCB006DS3 None published 18 8.5 1.8 20,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
214640012 4TXCC005DS3 None published 18 8.2 1.8 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
215453466 4TXCB006DS3 None published 18 8.2 1.8 20,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
215825872 4PX*CU36BS3 None published 18 8.2 1.82 20,200 Btu/h Xcel Energy Colorado Heat Pump Rebates
215825874 4PX*CU42BS3 None published 18 8.5 1.84 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
215825876 4PX*CU48BS3 None published 18 8.5 1.87 20,400 Btu/h Xcel Energy Colorado Heat Pump Rebates
216800006 4TXCB006DS3 None published 18 8.2 1.8 19,900 Btu/h Xcel Energy Colorado Heat Pump Rebates
216800008 4TXCB006DS3 None published 18 8.2 1.8 19,900 Btu/h Xcel Energy Colorado Heat Pump Rebates
207805685 4PX*BU36BS3+P0V0B000M40SC+RP None published 17.5 8.1 1.78 19,600 Btu/h Xcel Energy Colorado Heat Pump Rebates
207805689 4TXCB004DS3+P0V0B000M40SC+RP None published 17.5 8.1 1.78 19,600 Btu/h Xcel Energy Colorado Heat Pump Rebates

← Previous Page 2 of 2

What this result does not prove

A product-list match does not establish household, property, contractor, sizing, weatherization or remaining-funding eligibility. Installed Cost never states a rebate dollar amount. Follow the official program link for the current application rules and calculator.

Specifications reflect source records last updated Aug 8, 2026. ENERGY STAR is a registered certification mark; its name is used only to identify the federal source. Installed Cost is not endorsed by ENERGY STAR or AHRI.