Colorado
Xcel Energy Colorado Heat Pump Rebates
7 AHRI-linked records.
Published source date Mar 1, 2026. Metadata reviewed Jul 29, 2026.
FRASER-JOHNSTON heat pump
LX SERIES
Eligibility belongs to the complete outdoor-and-indoor combination—not just this outdoor model. Check the AHRI reference and indoor model in the table before relying on a result.
Check this complete system in Connecticut
AHRI links below are discovery evidence. They do not compare every model suffix or required component. Use the guided check for a full equipment comparison.
Colorado
7 AHRI-linked records.
Published source date Mar 1, 2026. Metadata reviewed Jul 29, 2026.
Wisconsin
5 AHRI-linked records.
Published source date Jun 18, 2026. Metadata reviewed Jul 29, 2026.
Showing 1–42 of 42. Performance values are combination-specific.
| AHRI reference | Indoor unit / coil | Furnace | SEER2 | HSPF2 | COP at 5°F | Capacity at 5°F | AHRI-linked list records |
|---|---|---|---|---|---|---|---|
| 214424718 | JHE60D5CH2SS1 | None published | 15.2 | 7.8 | 2.1 | 29,800 Btu/h | Xcel Energy Colorado Heat Pump Rebates |
| 214425504 | CTM60D5CJS1+JMC20D2SN1 | None published | 15.2 | 8.1 | 2.34 | 31,400 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 214425513 | CTM60D5CJS1+JMVT20DC2N1 | None published | 15.2 | 8.1 | 2.34 | 31,400 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 214425523 | CTM60D5CJS1+JME18D2SN1 | None published | 15.2 | 8.1 | 2.38 | 31,600 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 214426686 | CTM60D5CHS1+JMVT20DC2N1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214427824 | CTM60D5CHS1+JMET18DS2N1 | None published | 15.2 | 7.8 | 2.28 | 31,600 Btu/h | No stored match |
| 214428161 | CTM60C5CHS1+JME16C2SN1 | None published | 15.2 | 7.8 | 2.26 | 31,400 Btu/h | No stored match |
| 214428166 | CTF60D5CHS1+JME18D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,600 Btu/h | No stored match |
| 214428353 | CTM60D5CHS1+JMC20D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214428358 | JHC60D5CH2SS1 | None published | 15.2 | 7.8 | 2.3 | 31,600 Btu/h | No stored match |
| 214428363 | CTF60D5CHS1+JMC20D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214428885 | JHC60C5CH2SS1 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 214428895 | CTF60D5CHS1+JMVT20DC2N1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214429228 | CTM60D5CHS1+JME18D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,600 Btu/h | No stored match |
| 214429346 | CTF60D5CHS1+JMET18DS2N1 | None published | 15.2 | 7.8 | 2.3 | 32,200 Btu/h | No stored match |
| 214605351 | CTM60C5CHS1 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 214605466 | CTF60D5CHS1 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 214650136 | CTU60D5XHS1+TXV | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 214809114 | CTU60D5XHS1+JMET18DS2N1+TXV | None published | 15.2 | 7.8 | 2.3 | 32,200 Btu/h | No stored match |
| 214809119 | CTU60D5XHS1+JMVT20DC2N1+TXV | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214809124 | CTU60D5XHS1+JMC20D2SN1+TXV | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 214809129 | CTU60D5XHS1+JME18D2SN1+TXV | None published | 15.2 | 7.8 | 2.3 | 31,600 Btu/h | No stored match |
| 216782989 | CTM60C5CHS1 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 216783713 | CTF60D5CHS1 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 216783728 | CTU60D5XHS1+TXV | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 217444898 | CTF60C5CHS1 | None published | 15.2 | 7.8 | 2.28 | 32,400 Btu/h | No stored match |
| 217444899 | CTM60C5CHS1 | None published | 15.2 | 7.8 | 2.28 | 32,400 Btu/h | No stored match |
| 218457153 | JHE60D5CH2SS2 | None published | 15.2 | 7.8 | 2.1 | 29,800 Btu/h | Xcel Energy Colorado Heat Pump Rebates |
| 218525112 | CTF60C5CHS2 | None published | 15.2 | 7.8 | 2.28 | 32,400 Btu/h | No stored match |
| 218525206 | CTF60D5CHS2 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 218525210 | CTF60D5CHS2 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 218525222 | CTF60D5CHS2+JMVT20DC2N1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 218525230 | CTF60D5CHS2+JMC20D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 218525398 | CTM60C5CHS2 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 218525402 | CTM60C5CHS2 | None published | 15.2 | 7.8 | 2.26 | 31,600 Btu/h | No stored match |
| 218525422 | CTM60C5CHS2 | None published | 15.2 | 7.8 | 2.28 | 32,400 Btu/h | No stored match |
| 218525448 | CTM60D5CHS2+JMVT20DC2N1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 218525452 | CTM60D5CHS2+JMC20D2SN1 | None published | 15.2 | 7.8 | 2.3 | 31,800 Btu/h | No stored match |
| 218525476 | CTM60D5CJS2+JMVT20DC2N1 | None published | 15.2 | 8.1 | 2.34 | 31,400 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 218525480 | CTM60D5CJS2+JMC20D2SN1 | None published | 15.2 | 8.1 | 2.34 | 31,400 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 218637907 | CTF60D5CHS2+JME18D2SN2 | None published | 15.2 | 7.8 | 2.3 | 32,200 Btu/h | No stored match |
| 218637923 | CTM60D5CHS2+JME18D2SN2 | None published | 15.2 | 7.8 | 2.28 | 31,600 Btu/h | No stored match |
A product-list match does not establish household, property, contractor, sizing, weatherization or remaining-funding eligibility. Installed Cost never states a rebate dollar amount. Follow the official program link for the current application rules and calculator.
Specifications reflect source records last updated Jul 29, 2026. ENERGY STAR is a registered certification mark; its name is used only to identify the federal source. Installed Cost is not endorsed by ENERGY STAR or AHRI.