Colorado
Xcel Energy Colorado Heat Pump Rebates
3 AHRI-linked records.
Published source date Mar 1, 2026. Metadata reviewed Jul 29, 2026.
Tempstar heat pump
QuietComfort 19 SEER2 VS HP
Eligibility belongs to the complete outdoor-and-indoor combination—not just this outdoor model. Check the AHRI reference and indoor model in the table before relying on a result.
Check this complete system in Connecticut
AHRI links below are discovery evidence. They do not compare every model suffix or required component. Use the guided check for a full equipment comparison.
Colorado
3 AHRI-linked records.
Published source date Mar 1, 2026. Metadata reviewed Jul 29, 2026.
Connecticut
89 AHRI-linked records.
Published source date Aug 21, 2026. Metadata reviewed Sep 6, 2026.
Massachusetts
88 AHRI-linked records.
Published source date Jul 15, 2026. Metadata reviewed Jul 29, 2026.
Wisconsin
116 AHRI-linked records.
Published source date Jun 18, 2026. Metadata reviewed Jul 29, 2026.
Showing 101–200 of 212. Performance values are combination-specific.
| AHRI reference | Indoor unit / coil | Furnace | SEER2 | HSPF2 | COP at 5°F | Capacity at 5°F | AHRI-linked list records |
|---|---|---|---|---|---|---|---|
| 217918713 | EVM5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918803 | EVM5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918833 | EVM5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918863 | EVM5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918894 | EVM5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918909 | EVM5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918939 | EVM5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918954 | EVM5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217919421 | EVM5X61M24A* | None published | 16 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919436 | EVM5X61M24A* | None published | 16 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919843 | EVM5X61M24A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217919904 | EVM5X61M24A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217920024 | EVD5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920054 | EVD5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920099 | EVD5X60M21A* | None published | 16 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920144 | EVD5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920400 | EVD5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920445 | EVD5X60M21A* | None published | 16 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920897 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217920927 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217920942 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217920972 | EVD5X61M21A* | None published | 16 | 8 | 1.98 | 40,000 Btu/h | No stored match |
| 217920987 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921017 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921032 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921047 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217921062 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921137 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921212 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921242 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921272 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921318 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217921363 | EVD5X61M21A* | None published | 16 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217921453 | EVD5X61M24A* | None published | 16 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921815 | EVD5X61M24A* | None published | 16 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921845 | EVD5X61M24A* | None published | 16 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217931536 | EA*5X60M24A* | None published | 16 | 9 | 2.12 | 40,000 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931566 | EA*5X60M24A* | None published | 16 | 8.5 | 2 | 40,000 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931581 | EA*5X60M24A* | None published | 16 | 9 | 2.12 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931596 | EA*5X60M24A* | None published | 16 | 9 | 2.12 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931611 | EA*5X60M24A* | None published | 16 | 9 | 2.12 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931702 | EA*5X60M24A* | None published | 16 | 9 | 2.12 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931912 | EA*5X60M24A* | None published | 16 | 9 | 2.14 | 40,000 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217931972 | EA*5X60M24A* | None published | 16 | 9 | 2.14 | 40,000 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932092 | EA*5X61M21A* | None published | 16 | 8.5 | 2 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932167 | EA*5X61M21A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932497 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932512 | EA*5X61M24A* | None published | 16 | 9 | 2.12 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932632 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932648 | EA*5X61M24A* | None published | 16 | 8.5 | 2.05 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932738 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932828 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932873 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932918 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217932978 | EA*5X61M24A* | None published | 16 | 9 | 2.14 | 40,500 Btu/h | Focus on Energy Heat Pump Instant Discounts |
| 217933369 | F5MA5*60L*D* | None published | 16 | 9 | 2.16 | 40,000 Btu/h | Focus on Energy Heat Pump Instant DiscountsXcel Energy Colorado Heat Pump Rebates |
| 217918473 | EVM5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918623 | EVM5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918698 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918728 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918743 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918788 | EVM5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217918818 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918848 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918878 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217918924 | EVM5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217919361 | EVM5X61M24A* | None published | 15.5 | 8 | 1.98 | 40,500 Btu/h | No stored match |
| 217919391 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919406 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919481 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919511 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217919526 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919541 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217919707 | EVM5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217919979 | EVD5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920009 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920039 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920069 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920114 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920129 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 39,500 Btu/h | No stored match |
| 217920174 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 40,000 Btu/h | No stored match |
| 217920234 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 40,000 Btu/h | No stored match |
| 217920249 | EVD5X60M21A* | None published | 15.5 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217920294 | EVD5X60M21A* | None published | 15.5 | 8 | 1.96 | 39,500 Btu/h | No stored match |
| 217920369 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 40,000 Btu/h | No stored match |
| 217920385 | EVD5X60M21A* | None published | 15.5 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217920415 | EVD5X60M21A* | None published | 15.5 | 8 | 1.94 | 40,000 Btu/h | No stored match |
| 217920430 | EVD5X60M21A* | None published | 15.5 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217921092 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,000 Btu/h | No stored match |
| 217921152 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921167 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921287 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921303 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921333 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921348 | EVD5X61M21A* | None published | 15.5 | 8 | 1.96 | 40,500 Btu/h | No stored match |
| 217921378 | EVD5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921423 | EVD5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921438 | EVD5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921528 | EVD5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
| 217921558 | EVD5X61M24A* | None published | 15.5 | 8 | 1.96 | 41,000 Btu/h | No stored match |
← Previous Page 2 of 3 Next →
A product-list match does not establish household, property, contractor, sizing, weatherization or remaining-funding eligibility. Installed Cost never states a rebate dollar amount. Follow the official program link for the current application rules and calculator.
Specifications reflect source records last updated Aug 6, 2026. ENERGY STAR is a registered certification mark; its name is used only to identify the federal source. Installed Cost is not endorsed by ENERGY STAR or AHRI.